PLC 2500

With the capability to purify compounds by preparative HPLC and flash chromatography on the same instrument, Gilson's PLC 2050/2250/2500 Purification Systems simplify and streamline compound purification. These compact systems feature UV/VIS detection with an optional upgrade to a diode array detector (DAD) or evaporative light scattering detection (ELSD), an integrated pumping system, fraction collector, touchscreen control, and Gilson Glider Prep Software.

With the capability to purify compounds by preparative HPLC and flash chromatography on the same instrument, Gilson's PLC 2050/2250/2500 Purification Systems simplify and streamline compound purification. These compact systems feature UV/VIS detection with an optional upgrade to a diode array detector (DAD) or evaporative light scattering detection (ELSD), an integrated pumping system, fraction collector, touchscreen control, and Gilson Glider Prep Software. These customizable instruments are available in simple configurations for basic applications, but with a wide range of upgrade options to meet your lab's demands. PLC 2050 and PLC 2250 Purification Systems with Autosampler are configured with a VERITY® GX-241 Liquid Handler and VERITY 4020 Single Syringe Pump for automated sample injections for increased throughput. These systems allow you to queue samples and create multiple, unattended runs.

High Performance Features


• Intuitive touchscreen interface for easy method writing and modifying of parameters
• Built-in automatic injection valve
• Two or four independent solvent inlets for binary or quaternary gradients
• Three-rack fraction collector capacity with unlimited collection cycles
• Variable dynamic mixing chamber
• Dual reciprocating pump technology
• Four-wavelength UV/VIS or DAD detector
• Conductivity/pH monitor
• HPLC columns from 10 mm to 100 mm

PLC Purification System Models

PLC 2050: Flow rates up to 50 mL/min with pressure up to 300 bar
• Prep HPLC: 10-30 mm diameter ID columns
• Flash Chromatography: 2.5-70 g cartridges

PLC 2250: Flow rates up to 250 mL/min with pressure up to 230 bar
• Prep HPLC: 10-50 mm diameter ID columns
• Flash Chromatography: 10-600 g cartridges

PLC 2500: Flow rates up to 500 mL/min with pressure up to 110 bar
• Prep HPLC: 20-100 mm diameter ID columns
• Flash Chromatography: up to 1.2 kg cartridges

Specifications

PLC 2050/2250/2500 Purification Systems

Flow Rate/Max Pressure PLC 2050 PLC 2250 PLC 2500
50 mL/min, 300 bar (4 351 psi) 250 mL/min, 230 bar (3 336 psi) 500 mL/min, 110 bar (1 595 psi)
Flow Rate Performance 2% accuracy (with H2O degassed at 20°C)
Repeatability better than 0.5%
Linear response from 2 to 98 %

Binary Gradient (Standard)

or Quaternary (Optional) Injection

Automatic or manual injection through sample loop with injection valve (optional)
Additional injection pump (optional)
GX-241 Liquid handler (optional)
Gradient Binary Gradient (Standard)
Quaternary (Optional)
System Protection Software with minimum and maximum pressures adjustable
Control Via computer software “Gilson Glider Prep”
Storage Up to 32 methods in software memory and 80 GB of hard disk memory
AC Mains Supply Voltage 110V and 240 V ; 50/60 Hz (wattage: 350 W max.)
Electrical Protection Delayed action fuses T 6.3A H 250 V
Power Distribution TT or TN power system only, transient over-voltages according to installation category II, Class 1 equipment, requires mains socket plug with protective earth terminal
Switching Valve Column Switching Valve, Automatic (Optional)
Column Switching Valve Manual (Optional)

Column Size with

Optional Column Holder Kit

Maximum height: 400 mm

Maximum diameter: 115 mm

Detector Options Ultraviolet (UV) single wavelength detector, 254 nm filter
dual wavelength detector, 254 and 280 nm filters (optional)
UV detector 4-wavelength diode array detector (DAD) 200-400 nm (optional)
UV/VIS detector 4-wavelength DAD 200-600 nm (or 200-840 nm) (optional)
VERITY® 1900 MS detector (optional)
VERITY® 1810 Conductivity Monitor (optional)
PREPELS II Detector (optional)
Fraction Collector

Several rack options available.

Backflush valve (automatic)

Column switching valve (automatic or manual)

Fraction collector cover

Supporting Literature

Declaration of Conformity
PLC Purification Systems Declaration of Conformity Download (EN)    
Flyers
PLC Purification With CPC Column Download (EN)    
Technical Notes
Introduction to Centrifugal Partition Chromatography Download (EN)    
User Guides
PLC Purification User's Guide Download (EN)    

2023 Gilson Product Guide

The 2023 Gilson Product Guide is available now. Discover best sellers for your Liquid Handling, Purification, and Extraction needs!

Download

Gilson Services and Calibration Programs

Gilson is committed to quality and complete customer satisfaction with all of our products and services. Get system support, training programs and pipette service from the people who know Gilson products the best. We are here to help and provide you with dependable solutions to accommodate your needs.